备注
图片 | 物料 | 件数 | 单价 | 总价 | 总价,含折扣 | |
---|---|---|---|---|---|---|
|
{{warenkorbItem.produktgruppe.produktname}}{{warenkorbItem.bezeichnung | artikelBezFilter:warenkorbItem.attributwertEingaben:[{attrPrefix: 'L_', searchPattern: '/...', replacePrefix: '/', replaceSuffix: ''}] }} {{warenkorbItem.bezeichnung | artikelBezFilter:warenkorbItem.attributwertEingaben}}
{{attributwertEingabe.attributBezeichnung}}
|
|
||||
{{hannexItem.Benennung}}{{hannexItem.Bezeichnung}} |
|
The TCBOX has 12 thermocouple measuring inputs and can be placed directly on the connection box of the injection mould. This eliminates the need for thermocouple cables from the hot runner to the control unit. The high-resolution temperature values of the control zones are sent to the hot-runner controller via a thin data cable. This allows maximum savings in terms of costs, space and handling. For example, the number of connecting cables between the hot runner mould and the hot runner controller can be reduced by up to 50%.
Power supply | 24 VDC ±10% |
Power consumption | max. 3 W |
Quantity | 12 |
Thermocouple TC | Fe CuNi type L (-50...900°C) Fe CuNi type J (-55...1300°C) [default setting] NiCr Ni type K (-35...1372°C) NiCrSi-NiSi type N (-50...1300°C) Cu CuNi type T (-50...400°C) Pt10Rh-Pt type S (-50...1768°C) |
Measuring precision | < 1K |
Connecting cable | <30 m |
Transmission speed | 250 kBit (configurable) |
Addressing mode | 6-pin DIP switch (1-31) |
Bus termination | Can be activated via DIP switch 6 |
Connection | See connection |
Quantity | 1 |
Electrical data | 0...30 VDC, <10 mA at 24 VDC (optocoupler) |
Function | Cycle counter |
Mounting/installation | Mounting on hot runner mould connection box / recess according to 24-pin HAN E (see installation and connection) |
Ingress protection | IP 54 (if the connection box on the hot runner mould has an ingress protection of at least IP54) |
Depth | 44.5 mm |
Height | 58 mm (without push-in connection and grounding bolt) |
Width | 110 mm / 140 mm (with stop plate) |
Electrical safety | EN61010-1 |
EMC | EN 61326-1:2013, industrial requirements |
Overvoltage category | II |
Ingress protection | I |
Ambient temperature limit | Operation: 0...60 °C; transport, storage: -20...70 °C; |
Humidity limit | Relative humidity < 75% annual average, no condensation |
Sound pressure level | < 50 dB |
Pollution degree | 2 |
Installation altitude above sea level | Max. 2000 m |
In the Media & Downloads section you will find an overview of all product-specific documents.
For technical data such as user guides, service manuals, etc. please log in.
© 2022 by Meusburger Georg GmbH & Co KG | All rights reserved
若您已拥有Meusburger门户的访问数据,请在此登录:
新密码已生成,并将很快被发送至您的收件箱。我们祝您有顺利的一天。
试试我们新版的”我的账户“吧
熟悉我们新版的”我的账户“部分,众多便捷功能,包括: 熟悉我们新版的”我的账户“部分。